Safety
1.7
EU Declaration of Conformity
The products described in this document comply with the applicable European directives. The EU Declaration
of Conformity is available in the download area of our homepage www.kontron-solar.com.
2
Safety
2.1
Designated use
The SolBrid hybrid inverters are intended for the charging of a connected battery or the standard-compliant,
three-phase feed-in to the public power grid. Due to their IP65 protection class, the inverters are suitable for
fixed interior or exterior installation on a wall.
Only use the inverter:
for grid-connected PV generators.
for PV generators whose connections are not grounded.
for solar modules with Class A rating in accordance with IEC 61730 because the inverter does not have any
galvanic isolation.
if the entire voltage range of the PV generators and the battery lies within the input voltage range of the
inverter and the maximum DC input voltage is not exceeded.
for batteries that are intrinsically safe and approved by Kontron Solar GmbH.
with energy meters that are approved by Kontron Solar GmbH.
in countries for which they are approved or approved by Kontron Solar GmbH and the local grid operators.
Non-intended use is:
the use of the inverter in the medical field or to supply life-preserving devices.
any other use or use which goes beyond the points specified here.
2.2
Target group
The target group for these instructions are specialists who want to commission or decommission an inverter.
The following persons are considered specialists:
Persons that have knowledge of the established terms and skills for setting up and operating PV generators.
Persons that due to their knowledge and experience are able to evaluate the following tasks and recognise
possible hazards:
Mounting and installing electrical devices
–
Repairing electrical devices, batteries and systems
–
Assembling and connecting data cables
–
Assembling and connecting power supply cables
–
20
Installation and commissioning instructions
Z02 | 2404 | 780.767