Télécharger Imprimer la page

Kontron Solar SolBrid 10-3-2 Instructions D'installation Et De Mise En Service page 28

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Description
3.2
Function of the operating and display elements and connections
1
Item
Component
Green LED
1
Blue LED
2
Red LED
3
4
DC switch
5
PV+ and PV- ports
28
Installation and commissioning instructions
2
3
12
11
10
9
8
6
7
Function
Displays device status
Continuously lit
Flashes slowly
Flashes quickly
Displays WiFi status
Off
Continuously lit
Flashes slowly
Flashes quickly
Displays error status
Continuously lit
flashes slowly
(1 sec. on & 1. sec. off)
flashes quickly
(1/4 sec. on & 1/4 sec. off)
short (on)flashing
(1/4 sec. on & 3 sec. off)
Separates the connection to the PV modules
Connect to the PV modules (number depending on type variant)
4
5
Grid-connected operation
Emergency power supply active
Inverter is starting
Switched off and/or not configured
Connected to local network
Connection lost
WiFi Access Point active
Error
Measure: Start " SOL app", connect to
the inverter, click on "Events" tab
Configuration error, commissioning not
yet completed
Measure: Return to the commissioning
wizard
Service required
Warning: Power reduction active
Z02 | 2404 | 780.767

Publicité

loading

Ce manuel est également adapté pour:

Solar solbrid 10-3-4