Safety
DANGER
Risk of death by electrocution when working on the battery.
If the inverter is not switched to a voltage-free state, cables connected to the battery may be
live even if the battery is switched off.
f Switch the inverter to a voltage-free state before working on the battery and secure against
being switched on again.
DANGER
Risk of death by electrocution during emergency power supply.
The inverter has an emergency power function. Parts of the system may still be live even if
there is a power outage.
f Switch the inverter and the battery to a voltage-free state before working on the system
and secure against being switched on again.
f Make sure that the PE conductors of all connections in the emergency power circuit are
connected to the protective equipotential bonding.
DANGER
Risk of death by electrocution when inverter is open.
There are high voltages on voltage-carrying parts and cables inside the inverter.
f Do not open the inverter.
Please note: Opening the inverter will also void any warranty.
DANGER
Risk of death by electrocution after switching off.
Voltage can be present at the DC-connection for up to 10 minutes after switching off the DC
disconnector.
f Wait 10 minutes after switching off the DC disconnector and the battery.
WARNING
Risk of burning due to hot case parts.
The inverter case may become hot during operation.
f Do not touch hot surfaces.
f Wait until the inverter has cooled down before touching it.