OPERATION | INSTALLATION
Cleaning, care and maintenance
5.
Cleaning, care and maintenance
f Have the electrical safety of the appliance and the function of
the safety valve regularly checked by a qualified contractor.
f Have the protective anode checked by a qualified contractor
after the first two years of use. The qualified contractor will
then determine the intervals at which it must be checked
thereafter.
f Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Scaling
f Almost every type of water will deposit lime at high temper-
atures. This settles inside the appliance and affects both the
performance and service life. The heating elements must
therefore be descaled from time to time. A qualified contrac-
tor who knows the local water quality will tell you when the
next service is due.
f Check the taps regularly. Limescale deposits at the spouts
can be removed using commercially available descaling
agents.
f Regularly activate the safety valve to prevent it from becom-
ing blocked e.g. by limescale deposits.
6.
Troubleshooting
Problem
Cause
The water does not heat
There is no power.
up and the ON/OFF indi-
cator does not illuminate.
The water does not heat
The temperature is set
up sufficiently and the
too low.
ON/OFF indicator illumi-
nates.
The appliance heats,
for example, after large
amounts of DHW have
been drawn.
The flow rate is low.
The aerator in the tap
or the shower head is
scaled up or contami-
nated.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (no. 000000-0000-000000):
www.stiebel-eltron.com
INSTALLATION
7.
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2
8.
8.1
Remedy
The following are delivered with the appliance:
Check the fuses/MCBs in
- Wall mounting bracket (2 pce for appliances with 120 l and
your fuse box/distribu-
tion panel.
Select a higher temper-
- Spacers 5 mm (2 pce at the top / 2 pce at the bottom; for ap-
ature.
Wait until the ON/OFF
8.2
indicator goes out.
8.2.1 Required accessories
Clean and/or descale the
aerator or shower head.
Various safety assemblies are available for sealed unvented (pres-
sure-tested) operation, depending on the static pressure. These
type-tested safety assemblies protect the appliance against im-
permissible excess pressure.
8.2.2 Further accessories
Caps
Nr.: 000000-0000-000000
Made in Germany
1 Cap
Caps (two pieces per pack), part number 150428
Appliances in excess of 120 l require two packs.
Safety
General safety instructions
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
Appliance description
Standard delivery
150 l nominal capacity)
pliances with 120 l and 150 l, 4 pce at the top / 4 pce at the
bottom)
Accessories
1
SH A |
19