Delay
With the "Manual" setting, the alarm output is not reset after an event. This must then be confirmed and reset
manually by clicking the "Manual alarm" button twice.
The regular activation time of the output after an event is 5 seconds. A further active time of up to 10 minutes
can be programmed.
Alarm name
Here you can assign a name for the respective alarm output. Please do not use the alarm output no. or any
special characters.
Timetable
To store a schedule, click on "Activate schedule". Specify the days of the week and times at which the alarm
output should be active.
The time period is selected by marking it with the left mouse button. By clicking on an already selected
period, the details can also be set or deleted using the keyboard.
To copy the time selection to other days of the week, move the mouse pointer behind the bar of the day of
the week that has already been set and use the "Copy to ..." function.
Please accept the settings you have made by clicking "Save".
8.9.9 Acoustic alarm output
The acoustic alarm output can play predefined sounds or customised short sound media. This function can
only be used with a camera with audio output or integrated loudspeaker.