The standard port for the RTSP transmission is 554. Alternatively, this port can be given a value in the range
of 1025~65535. If there are several IP cameras in the same subnet, each camera should be assigned its
own unique RTSP port.
Server port (control port)
The standard port for SDK transmission is 8000, communication port for internal data. Alternatively, this port
can be given a value in the range 1025~65535. If there are several IP cameras in the same subnet, each
camera should be assigned its own unique SDK port.
External port
You can only change the ports manually if the "Mapping Port Type" has been changed to Manual.
Status
Indicates whether the external port entered is valid or invalid.
Not all routers support the UPnP port mapping function (also known as Auto UPnP).
8.4.14 ABUS LINK STATION
The ABUS Link Station function is used for simple remote access to the ABUS device via the Link Station
APP (iOS / Android). Products can be easily set up and released via QR code - without complicated
configurations in the router (no port forwarding necessary).
Activate the function and assign a verification code (6-12 characters, A-Z, a-z, 0-9, at least 2 different
character types recommended).
The QR code can then be photographed in the ABUS Link Station APP.
Push function in ABUS Link Station APP
1.
activate ABUS Link Station function in IP camera
2.
add IP camera to the ABUS Link Station app via QR code or 9-digit serial number part
3.
activate push notification in the app (More/Function settings/Push notification)
4.
activate "Alarm notification" in the individual camera settings in the Link Station app.
5.
activate and configure the desired detector in the IP camera (motion detection, tripwire or intrusion
detection)
6.
activate "Event-controlled single image recording" in the IP camera under Storage/Single image
recording/Capture parameters
7.
add rule in Event Manager in IP camera and select "Notify NVR/CMS" as action
116