Impeller Replacement

First: Turn off power to the pump, disconnect the
discharge piping, and lift the pump out of the
sump BY THE RING ON TOP OF THE MOTOR
(not by the cord).
Step 1: Remove the three screws holding the
motor to the base and lift the motor off the base.
Step 2: Hold the motor shaft with a screwdriver
and unscrew the impeller as shown.
NOTICE: The impeller has a left-hand thread, so
it loosens to the right (
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
6167 0310
).
Step 3: Thread the new impeller onto the motor
shaft as shown (left-hand thread – tightens to the
left
).
Step 4: Re-mount the motor on the base. Be
sure to mount it so that the switch is clear of the
discharge and all other obstructions in the sump.
Last: Run the pump through one complete cycle
after it is assembled and reinstalled. It should
operate correctly and you should not hear any
sounds of scraping or dragging from the pump.