Installation
10" Min. with
IntelliShield
Switch
Figure 1
1A. Minimum sump size: 10" (254mm) diameter
by 10" (254mm) depth.
1B. Construct the sump pit of tile, concrete, steel,
or plastic; it must meet code requirements.
1C. No clay, earth, sand, or gravel in the sump
(they will clog the pump). Keep the pump inlet
screen clear.
Figure 2
2A. Install the discharge plumbing and check
valve, using PTFE pipe thread sealant tape,
NOT pipe joint compound.
2B. Tighten the pipe into the pump (hand tight
+ 1-1/2 turns).
2C. A check valve in the vertical pipe prevents flow
backwards through the pump when it shuts off.
To prevent airlocking the pump, drill a 1/8"
(3.2 mm) hole in the discharge pipe just above
where it screws into the pump discharge. Install
the check valve above this hole, but keep it
as close to the pump as possible. Be sure the
hole is below the waterline and below the
check valve.
2D To reduce noise and vibration, cut the
discharge pipe near the pump and fasten
a short length of rubber hose (1-7/8"
(48 mm) I.D., e.g. radiator hose) into it with
hose clamps.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
10" Minimum with
IntelliShield Switch
Sump Pit
Hard Surface –
No Sand, Clay,
Gravel
3A. Unsnap the switch from the switch bracket and
remove it from the pump (see Figure 11).
Figure 3
3B. Slide the lid down over the discharge pipe.
3C. Remove the cord grommet from the sump
lid and pass the switch down through the
grommet hole in the lid (Figure 4).
Figure 4
3D. Pull the pump power cord up through the
grommet hole.
3E. Press the power cord and switch cord into
the slots in the grommet and replace the
grommet in the sump lid. Snap the switch into
the bracket.
Figure 5
3

Publicité