INSTALL MOUNTING
BRACKET
1. Construct wood wall framing that is flush
with interior surface of wall studs.
Make sure:
a) the framing is centered over
installation location.
b) the height of the framing will allow the
mounting bracket to be secured to the
framing within the dimensions shown.
2. After wall surface is finished, secure mount-
ing bracket to framing using dimensions
shown.
CEILING HEIGHT
24"
37-7/8"
8 FEET
9 FEET
10 FEET WITH
37-7/8"
FEXTK7788
Note: minimum hood distance above cook top must not be less than 24". A maximum
of 30" above cook top is highly recommended for best capture of cooking impurities.
Distances over 30" are at the installer and users discretion; and if ceiling height and
flue length permit.
IN-LINE BLOWER
HOOD DISTANCE ABOVE 36" HIGH COOK TOP (SEE NOTE BELOW)
25"
26"
MOUNTING BRACKET LOCATION ABOVE 36" HIGH COOK TOP
38-7/8"
39-7/8"
38-7/8"
39-7/8"
38-7/8"
39-7/8"
FRAMING BEHIND CROSS SUPPORT
WOOD CROSS SUPPORT
BEHIND DRYWALL
27"
28"
40-7/8"
41-7/8"
40-7/8"
41-7/8"
40-7/8"
41-7/8"
- 9 -
DRYWALL
29"
30"
42-7/8"
42-7/8"
43-7/8"
42-7/8"
43-7/8"