7. Starting, operation
Index
Object
(decimal)
Name
76
DR1
77
DS2
78
DR2
240
MBA
241
MBE
250
DISR
251
DISM
252
PAS
253
LOCK
20
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio PSD-30
Format
Access Value range
16 Bit unsigned R/W
16 Bit unsigned R/W
16 Bit unsigned R/W
32 Bit IEEE 754
R
Float
32 Bit IEEE 754
R
Float
8 Bit Enume-
R/W
ration
8 Bit Enume-
R/W
ration
16 Bit unsigned R/W
8 Bit Enume-
R/W
ration
0 ... 50,000 (0 ... 50 s)
0 ... 50,000 (0 ... 50 s)
0 ... 50,000 (0 ... 50 s)
-
-
0 = standard
1 = 180° rotated
0 = Act
1 = HIGH
2 = LOW
3 = SP1/FH1
4 = RP1/FL1
5 = SP2/FH2
6 = RP2/FL2
7 = Off
0 ... 9999
0 = Unlocked
1 = Locked
Factory
setting Note
Switch delay time
0
Reset point 1
Switch delay time
0
Reset point 2
Switch delay time
0
Reset point 2
The pressure value is
always linearised in
such a way that the
1000
MBA matches the value
1000 and the MBE
matches 9000.
The pressure value is
always linearised in
such a way that the
9000
MBA matches the value
1000 and the MBE
matches 9000.
0
Display rotate 180°
Display value in
0
Display-Mode
Password input for
parameter adjustment
-
at the instrument. Pass-
word 0 = no password
0
Global keylock
GB