7. Starting, operation
Specifications
Power supply U+
Signal output and
maximum ohmic load R A
Setting time (Analogue signal)
Current consumption
Total current supply
Switch points
Type
Number
Function
Contact rating
Switching current
Response time
Accuracy
Insulation voltage
Display
Design
Accuracy
Update
Accuracy
Non-linearity
Long-term drift
10
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio PSD-30
Model PSD-30
DC 15 ... 35 V
R
in Ohm
4 ... 20 mA, 3-wire
A
0 ...10 V, 3-wire
Adjustment zero point offset, max. 3 % of span
ms
3
mA
max. 100
mA
max. 600 (max. 500 with IO-Link) incl. switching current
Individually adjustable via external control keys
Transistor switching output PNP or NPN
1 or 2
normally open / normally closed; windows- and hysteresis function
freely adjustable
DC V
Supply voltage U+ - 1 V
SP1: 250 (100 mA with IO-Link)
mA
SP2: 250
≤ 10
ms
% of span
≤ 0.5 (setting accuracy)
DC 500 V
14-Segment-LED, red 4-digits, height 9 mm
electronic 180° rotatable
≤ 1.0 ± 1 Digit
% of span
ms
100, 200, 500, 1000 (adjustable)
≤ 1.0 *
% of span
)
*
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
)
error of measurement per IEC 61298-2)
≤ ± 0.5
% of span
≤ 0.2
% of span
RA ≤ 0,5 k
RA > 10 k
(SP1 = PNP with IO-Link)
(BFSL) according to IEC 61298-2
according to IEC 61298-2
GB