7. COMPLETING THE INSTALLATION
7.1. Anti-tipping safety assembly
If the appliance(s) is not connected
through the side profile trims to secured
cabinetry you must install the anti-tip
brackets to ensure the product does
not fall forward during use and cause
damage or injury. Failing to secure the
appliance(s) securely will void any war-
ranty claim attributable to a tipping situ-
ation.
Operate as follows:
>
The brackets should be applied as illustrated
using the provided screws If using the anti-tip
brackets, lag into wood framing or concrete -
drywall will not hold the weight of appliance.
Place a bracket on the top of the appliance in
correspondence to the fixing holes and against
the wall [ 1 ].
" )
⁄
1
4 5 (
1
>
Mark up the holes position on the wall [ 2 ].
2
BOTTOM COMPRESSORS
UNIT
32
TOP COMPRESSORS
UNIT
www.smeg.com
>
Drill the wall with an 8 mm (3/8") bit and in-
sert the expansion plug [ 3 ].
3
>
Reposition the bracket and fix it first to the
cabinet and then to the wall [ 4 ].
4
BOTTOM COMPRESSORS
MODEL
In order to use the anti-tip brackets on
the top compressor models, it will be
necessary to temporarily remove the
top, metal ceiling / shield to access the
bolting points for the brackets.
2 x
6 x
TOP COMPRESSORS
MODEL