Specification
5
Specification
5.1
Dimensions and connections
WPKI-HKV 2
524
125
125
125
e02
e01
e02
e01
d33
d34
D0000115600
WPKI-HKV 3
774
125
125
125
125
e02
e01
e02
e01
d34
d33
D0000115401
d33
Heat gener-
ator flow
d34
Heat gener-
ator return
e02
Heating re-
Male thread
turn
e03
Heating flow
Male thread
optional
5.2
Data table
Application limits
Max. permissible
°C
temperature
Max. permissible
MPa
pressure
Connections
Connection, above
Connection, below
6
Guarantee
The guarantee conditions of our German companies do not ap-
ply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only granted
if the subsidiary has issued its own terms of guarantee. No other
guarantee will be granted.
6
| WPKI-HKV
70
85
173
125
e02
e01
70
85
173
WPKI-
WPKI-
HKV 2
HKV 3
1''
1''
1''
1''
1 1/2''
1 1/2''
1 1/2''
1 1/2''
WPKI-HKV 2
WPKI-HKV 3
206638
206637
110
110
0.60
0.6
G 1 1/2
G 2
G 1 1/2
G 2
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products. This
will not affect warranties issued by any importers.
7
Environment and recycling
u Dispose of the appliances and materials after use in accord-
ance with national regulations.
u If a crossed-out waste bin is pictured on the ap-
pliance, take the appliance to your local waste
and recycling centre or nearest retail take-back
point for reuse and recycling.
This document is made of recyclable paper.
u Dispose of the document at the end of the appli-
ance's life cycle in accordance with national reg-
ulations.