Télécharger Imprimer la page

GMP COLIBRI VORTEX 60 Serie Manuel D'emploi Et D'entretien page 26

Publicité

Les langues disponibles

Les langues disponibles

9 – DISPOSAL
INFORMATION TO USERS
pursuant to Legislative Decree No. 49 of March 14, 2014
"Implementation of Directive 2012/19 / EU on Waste Electrical and Electronic Equipment (WEEE)"
This wheeled bin symbol on the product indicates that at the end of its life must be collected separately
from other waste. The user must, therefore, take the remote control integrates the essential
components that got to its life to the appropriate differentiated collection centers for electronic and
electro-technical waste, or return it to the dealer when purchasing a new appliance of equivalent type,
in terms of one to one, or one to zero for equipment having longer side of less than 25 cm. Appropriate
separate collection for the decommissioned equipment for recycling, processing and environmentally
compatible disposal helps prevent negative impact on the environment and human health and
promotes recycling of the materials making up the product. Illegal dumping of the product by the user
entails the application of administrative sanctions stated in Legislative Decree n. Legislative Decree No.
49 of March 14, 2014.
10 - TROUBLESHOOTING
FAULT OR INCONVENIENT
The motor does not start
and makes no noise.
Pump does not deliver
Insufficient Flow/Pressure
The electric pump does not
stop
The electric pump stop after
running for a short time.
The thermal switch intervenes
Pag 26 / 40
G.M.P. S.p.A. Via Sale 119/121 – 25064 Gussago (BS) Italy
PROBABLE REASONS
No electric power.
Circuit breaker tripped.
Float blocked.
Thermal protection tripped.
Protection fuses blown.
Faulty motor or capacitor.
Suction hole or pipe obstructed.
The impeller is worn or blocked.
Check valve blocked.
Manometric height is too high.
See causes above.
Water level too low.
No supply voltage correct.
Incorrect direction of rotation of
the motor (in three-phase
pumps).
The float remains inserted.
The thermo-amperometric
protection device stops the
electric pump.
Faulty capacitor.
The rotating part is blocked.
Damaged line cord.
Incorrect voltage.
Pumped liquid too hot and/or
too thick
.
Internal defect.
The rotating part is blocked.
REMEDY ACTIONS
Check the voltage and check the power cord.
Check the cause and reset it if necessary.
Verify that the starting level is reached.
Reactivate it if this is not automatic.
Provide for their replacement with fuses of the same
type.
Contact the dealer or the manufacturer.
Clean and remove obstruction.
Replace impeller or remove obstruction.
Clean it and check for correct operation.
Check the system and the characteristics of the pump.
Turn off the pump.
Check that the voltage is the one indicated on the plate.
Check the direction of rotation.
Check that the float is not blocked and that it moves
freely.
Remove any foreign bodies. Wait for the thermal
protection switch to trip again.
Replace the capacitor.
Check and remove obstruction.
Repair or replace cable.
Check voltage.
Pump liquid with lower temperature and/or density
Contact the dealer or the manufacturer.
Check and remove obstruction.
.
File: FiGMP002_Rev.4 Data_01-2023