11. Adjusting the water flow
May only be carried out by a specialist.
Remove the cover (see Fig. 11), undo the hood screw underneath and remove the hood.
Decreasing the flow rate:
Turn the adjusting screw clockwise to decrease the flow rate, thus making a higher outlet tem-
perature possible.
Increasing the flow rate:
Turn the adjusting screw counter-clockwise to increase the flow rate, thus reducing the pos-
sible outlet temperature.
9
Direction
12. Adjusting the water temperature
10
Tem pe ra ture
Flow
in crease
–
+
+
–
25
The factory set hot water outlet temperature
is 45 °C.
This factory setting can be modified within
the range of approx. 30 °C to 45 °C by turn-
ing the readout potentio meter with a slotted
screwdriver (width approx. 2 mm).
The hot water outlet temperature will
be decreased by clockwise rotation and
increased by counterclockwise rotation.