6. Installing and water connection
3
1. First, screw in the special fittings with the cover plate to a ½ inch water connection onto a
wall and seal using a suitable sealant. Both ⅜ inch water connections must face vertically
upwards.
2. Install pipe extensions to the tap with compression connectors according to installation dia-
gram on the mounting template. Determine the position of the appliance using the mount-
ing template and then dowel and fit wall bracket using screws.
3. Hook appliance onto wall bracket and insert pipe extensions into the water connections of
the appliance. Click appliance into place. Screw pipe extensions with compression connec-
tors to the appliance. Use a spanner to hold the instantaneous water heater water connec-
tions steady as you do so.
4. Fit sprayhead and screw to fitting.
5. After installation, carefully check all connections for leaks and rectify as necessary.
4
d
a
a. Seal
b. Strainer
e
c. Cold water-connection (inlet)
d. Hot water-connection (outlet)
c
a. Seal
e. Rating plate cover
b. Filter
c. Cold water connection (inlet)
b
d. Hot water connection (outlet)
a
e. Rating plate cover
21
CLAGE
EN