Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an "Instruction Manual" which should be read
carefully as it provides important information about safety, installation, ope-
ration and maintenance.
This product complies with recognised technical standards and safety regula-
tions. We declare that it is in conformity with the following European Directives:
89/336/EEC, 73/23/EEC, 98/37/EEC and subsequent amendments.

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing closing
structures (door, gates etc.), as well as from any deformation which might
occur during use.
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) GENERAL OUTLINE

The HYDRA-R control panel is suitable for controlling 1 or 2 PHEBE series
operators, designed to automate different types of overhead doors.
The panel can be either
fitted on board the PHEBE series (fig. 1) or
-
-
wall-mounted (fig. 2), when to be used for the series having no control
units on board (PHEBE – SQ series).
For automation of an overhead door with two motors, 2 configurations are
possible:
12 -
HYDRA-R - Ver. 05
INSTALLATION MANUAL
-
no. 1 PHEBE + no. 1 PHEBE -SQ
no. 2 PHEBE -SQ + no. 1 HYDRA-R with panel, wall mounted.
-
This control panel is supplied by the manufacturer with standard function
setting. Any modification must be set by means of the incorporated display
programmer or by means of UNIPRO. The control unit fully supports the
EELINK protocol.
These are the main innovative characteristics of the HYDRA-R control
panel:
-
management of one or two 24 V
-
management of on-board receiver according to the new type of radio-
transmitter cloning
-
presetting for operation by means of local and centralised commands via wire.

3) TECHNICAL SPECIFICATIONS

Power supply: .............................................................. 230V
Mains/low voltage insulation: .......................................> 2M Ohm 500 V
Working temperature: ............................................................. -10 to +55°C
Dielectric strength: ........................mains/low voltage 3750 V~ per 1 minute
Maximum power: ............................................................... 80W (2 PHEBE)
Blinker: ................................................................................ 24 V
Courtesy light: ..................................................................... 24 V
Gate-open warning light:........................................................ 24V
Power supply for accessories: ........................24V
Incorporated rolling-code radio receiver: ................. 433.92 MHz frequency
Coding: ................................................. rolling-code algorithm to be cloned
No. combinations: .......................................................................... 4 milliard
Antenna impedance: ...........................................................50 Ohm (RG58)
Max. no. radio transmitter to be memorised: ............................................ 63
Dimensions: ...............................................................................see figure 1
(* other voltages available on request)
4) TERMINAL BAR CONNECTIONS (Fig. 3)
WARNING – During wiring and installation, refer to the current standards
as well as to principles of good technical practice.
Arrange the layout of the electrical installation, making reference to the
current electrical CEI 64-8 and IEC 364 standards, HD384-harmonised, or
other national standards. Keep the mains power supply connections distinctly
separate from the service connections (photocells, electric edges, control
devices etc.)
JP2
1-2
JP7
3-4
5-18
6-7
8-9
10-11
10-12
13-14
13-15
16-17
19-20
21-22
23-24
25
26
27-28
JP3 (F) JP4 (N)
~
230V
output to transformer
JP5 + JP6 -
24V
input from transformer or battery back up
N.B. The board is provided with a series of pre-wired jumpers to make work
easier for the installer.
The jumpers involve the following terminals: 10-11, 10-25, (13-14, 13-15
PHEBE-SQ). If the above-mentioned terminals are used, remove their
respective jumpers.
+ torque
Single-phase mains power supply (1=N) (2=L)
Connection to motor 1:
3 - motor (BLUE wire)
4 - motor (BROWN wire)
PHEBE-SQ lamp control output (fig. 3c)
24 V
electric lock or 24V 3W (DIP LG2) max. flashing light.
~
24V
200mA max output – supply to photocells or other devices
STOP button input (N.C.). If not used, leave the jumper bridged.
START button input (N.O.)
Motor opening limit switch (N.C.). If not used, leave the jumper
bridged.
Motor closing limit switch (N.C.). If not used, leave the jumper
bridged.
Connection to motor 2:
16 - motor (BLUE wire)
17 - motor (BROWN wire)
~
24V
output for blinking light (25W max)
~
Output (N.O. contact (24V
/0.5A max)) for gate-open warning light
or alternatively 2nd radio channel (fig. 3a)
~
24V
V safe 180mA max output – supply to photocell transmitters
with check (fig. 3b)
Photocell input (N.C,). If not used, leave jumper 10-25 bridged (fig.
3b).
Fault input (N.O.). Input for photocells provided with N.O. checking
contact (fig. 3b).
Antenna input for plug-in radio-receiver board (27 signal - 28
braid)
~
±10% 50 Hz*
~
25W max
~
25W max
~
3W max
~
(0.2 A max absorption)