6 orange and lazy fire,
piled pellet, carbon on
the glass
7 The fire put out and
power is off automatically.
8 The blower still works
after the stove is cool and
fuel feed stops.
Lack of air intake for
burning.
The hopper is empty.
No fuel feed.
The fuel feed is too little.
low temperature switch
(30˚C) is wrong. Set
temperature is reached
The low temperature
switch (30˚C) is broken.
80
Clean the block in gate bar. Check
the door and window glass gasket
sealed or not.
Check the air intake pipe and venting
pipe blocked or not and clean it.
Change to the big diameter pipes if
pipes are too long to affect
combustion.
Adjust the combustion fan's speed up
Call the dealer to reset the program
Put fuel into the hopper. refer to (2)
Lower the speed of combustion fan
Cool the stove at least 1 hour then
operate again or change the low
temperature switch (30˚C).
"ECO" its normal, waiting, after the
temperature is blow set on, it will
automatically switch on again
Change this switch.