CLEANING THE CONVECTION BLOWER
To clean the convention blower, Disconnect the stove power cord from the electrical outlet.
Remove the side panels and rear panel (For all models). A vacuum can be used to remove any
dust accumulation on the blower's blades or inside the blower duct. Caution should be used
not to damage the blower's blades during cleaning.
CLEANING THE VENT PIPE
Soot and Fly ash: Formation and Need for Removal
The products of combustion will contain small particles of fly ash will collect in the exhaust
venting system and restrict the flow of the flue gases. Incomplete combustion, such as
occurs during start up, shutdown, or incorrect operation of the room heater will lead to
some soot formation which will collect in the exhaust venting system. The exhaust venting
system should be inspected at least once every year to determine if cleaning is necessary.
Sweep the pipe as needed.
A tee and the cleanout in the vent system attached to the stove's flue collar will facilitate this
cleaning.
Required Cleaning Schedule after Number of Bags Burned
Burn Pot=10 bags
Ash Drawer=50 bags Flue
Fan=100 bags
Blower=100 bags
NOTE: Cleaning schedule will depend on quality of pellets used. Burned high ash pellets used.
Burned high ash pellets will require more frequent cleaning
75