or unsealed ash drawer, the vacuum
switch will sense it and cause the heater to go into a shutdown mode.
AUGER AND AUGER MOTOR
The 2 RPM auger motor turns the auger lifting pellets up the auger tube. The pellets are then
dropped down a tube and into the firepot. The auger is controlled by the control board.
OVER TEMPERATURE THERMOSTAT
This safety switch is installed on the bottom of hopper and will shut off the heater if it senses
excessive temperatures (70 degrees).
CONVECTION BLOWER THERMOSTAT
This switch is installed on the vent pipe and turns the convection blower on when the heater
is above 40 degrees.
23.Room temperature Sensor. 24. Handle. 25 Stove Feet. 27. Safety temperature S
The heater is mainly made up of
following items - 1. Combustion burn
pot 2. Exhaust fan 3. Room circulation
fan and auger motor.
The following is a list of main
components and their functions:
The HEATER comes equipped with an
automatic electric igniter for lighting
the fuel when the heater is in lighting
mode only. The igniter remains
energized for the first eight minutes of
the lighting sequence.
VACCUM SWITCH
The HEATER has a safety vacuum
switch located behind the left door,
fastened to the base. If a low pressure
is created in the firebox by a leak,
opening the front door, a blocked flue,
47
IGNITER

Publicité