A:17. Socket for boom microphone
A:18. Charging socket
Accessories and spare parts
B:1. Hygiene kit HK3B: 380684118
B:2. Sweat absorbers CR1: 380684035
B:3. Windshield boom microphone: 380684084
B:4. Battery charger: 380684050, 380684100
B:5. Rechargeable AA batteries: 380684068
B:6. 3,5 mm stereo connection cable: 380684043
B:7. Boom microphone: 380684076
B:8. Windshield level dependent microphones: 380684092
B:9. Spare Headband: 380684120
B:10. Spare Helmet Arm (pair): 380684123
Change of hygiene kit (pic. E)
1. Remove the old sound absorber foam and insert the new
2. Pull off the old ear cushion
3. Centre the new ear cushion over the hole
4. Press with a finger along the outside of the ear cushion until it attaches all around the edges
5. (only for headband models) Pull off the old head cushion and insert the new
Important!
Earmuffs, and in particular cushions, may deteriorate with use and should be examined at
frequent intervals for cracking and leakage.
Hygiene kit should be changed at least twice per year. Make sure you choose the correct hygiene kit for your
hearing protector. (B:1)
Approval and technical data (see table F)
F:1) Headband
F:2) Helmet mount
F:3) Tested and certified to (standards)
F:4) Weight
F:5) Mean attenuation
F:6) Standard deviation
F:7) Assumed Protection Value
F:8) Tested and certified by (notified body)
F:9) Electrical input level (3,5 mm AUX)
F:10) Size
Approved helmet combinations
These earmuffs should be fitted to, and used only with the industrial safety helmets listed in table G.
G:1) Manufacturer
G:2) Model
G:3) Adapter
Earmuffs complying with EN 352-3 are of medium size range or small size range or large size range. Medium
size range earmuffs will fit the majority of wearers. Small size range or large size range earmuffs are designed
to fit wearers for whom medium size range earmuffs are not suitable.
Canada Compliance Statement
CAN ICES-3 (B)/NMB-3(B)
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and
Economic Development Canada's licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the
device.
L'émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d'Innovation,
Sciences et Développement économique Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes :
1) L'appareil ne doit pas produire de brouillage;
2) L'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
13