4. Where an alternative internal pressure sensor is used
it must be a certified device and installed in accordance
with the terminal parameters and any conditions of safe
use applied to them.
5. Where a remote sensor is connected to Channel 2, the
remote sensor must be disconnected from all other
power sources.
1.3.6 US and Canada Hazardous Area Location
information
Refer to Control Drawing 171M9042 for additional cULus
installation information.
1.3.7 Declaration requirements
EU Directive 2014/34/EU - This instrument obeys the
necessary health and safety specifications not specified by
'EU' Type Examination Certificate SGS21ATEX0009X
when installed as instructed in this manual.
UKSI 2016:1107 - This instrument obeys the necessary
health and safety specifications not specified by UK Type
Examination Certificate BAS21UKEX0638X when installed
as instructed in this manual.
1.4 Over-voltage categories
Over-voltage
Category
This is the least dangerous over-voltage
transient. CAT I equipment cannot be directly
CAT I
connected to the mains power. An example of
CAT I equipment is a process loop-powered
device.
This is for single phase electrical installation.
CAT II
Examples are appliances and portable tools.
1.5 Repair
WARNING
The service or repair of the
instrument can result in damage to property
and serious personal injury (including death).
It is important that service and repair work is
only done by a Druck approved service
provider.
Repair activities done by not approved
personnel can cancel the instrument
warranty. Druck cannot be held liable for
damage. This damage can include damage to
the equipment or a monetary fine. Personal
injury (including death) can occur because of
service maintenance or repair work done by a
service provider that is not approved.
Internal components can be under pressure or
be a source of other hazards if not used
correctly.
For more information, please see:
bakerhughesds.com/druck/global-service-support
1.6 Maintenance and Inspection
The instrument must be periodically inspected for signs of
damage (for example, case cracking, pressure connector
Description
damage) or pressure leakage before use, to be sure of
continued safe operation.
INFORMATION
the source of the failure to keep constant
pressure. Other sources of leakages can be
seen fluid leakage (hydraulic devices) or
heard air leakage (pneumatic devices).
For details, please see:
bakerhughesds.com/druck/global-service-support
Use a damp cloth with water and mild detergent, to clean
the surface of the instrument. Do not fully put the
instrument into water.
To calibrate the instrument, or for further information
please contact:
bakerhughesds.com/druck/global-
service-support
1.7 Disposal
For more information contact:
Our Customer Service Department:
Druck.com/expert
Your local government office.
1.8 Environmental Conditions
Condition
DPI610E
Not for permanent
Outdoor Use
installation outdoors
IP Rating
IP54
Operating
-10 to 50°C
Temperature
Storage and
Transport
-20 to 70°C
Temperature
Altitude
-300 to 2000m
0 to 95% relative
Operating humidity
humidity (RH) non-
condensing
Over-voltage
2
category
Pollution degree
1
English–DPI 610E Quick Start & Safety Manual | 3
Pressure leakage can be
Do not dispose of this
product as household
waste.
Use an approved
organization that collects
and/or recycles waste
electrical and electronic
equipment.
Mains Plugtop
149M4334 1
For indoor use only
IP20
0 to 45°C
-20 to 70°C
-300 to 2000m
0 to 95% relative
humidity (RH) non-
condensing
2
1
Copyright 2022 Baker Hughes Company.