• The installation will comply with all clearance requirements
and applicable standards and regulations.
• A suitable isolating switch providing full disconnection from
the mains power supply is incorporated in the permanent
wiring, mounted and positioned to comply with the local
wiring rules and regulations.
• The isolating switch must be of an approved type and
provide a 3 mm air gap contact separation in all poles (or
in all active [phase] conductors if the local wiring rules
allow for this variation of the requirements).
• The isolating switch will be easily accessible to the customer
with the hob installed.
• You consult local building authorities and by-laws if in
doubt regarding installation.
• You use heat-resistant and easy-to-clean finishes (such as
ceramic tiles) for the wall surfaces surrounding the hob.
After installing the hob, make sure that
• The power supply cable is not accessible through cupboard
doors or drawers.
• There is adequate flow of fresh air from outside the
cabinetry to the base of the hob.
• If the hob is installed above a drawer or cupboard space,
a thermal protection barrier is installed below the base of
the hob.
• The isolating switch is easily accessible by the customer.
Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use
the packaging). Do not apply force onto the controls
protruding from the hob.
67