ENGLISH
branch.
3. Secure it with a hose clamp (tightening moment: 1.5 Nm).
Make sure that the outlet end of the hose is securely sealed.
Installation in a pre-wall
5. Secure the Hebefix Mini against buoyancy and to prevent
twisting! Screw the unit firmly to the floor with the provided
fasteners.
Wall mounting
Wall mounting is possible for both of the long sides of the tank.
1. Screw the two brackets to the wall with a spacing of 172 mm.
Use the drilling template provided on the last page of this
manual.
2. Use the elongated holes to align the unit horizontally.
3. Position the rubber spacer below and midway between the
two brackets and screw it to the wall.
4. Lift the HEBEFIX MINI into place with its slots over the
brackets.
5. Adjust its position slightly if necessary.
10
Emergency drainage
For emergency drainage pur-
poses, you can install a length
of garden hose at the bottom
right of the tank to drain away
the water accumulated in the
tank.
1.
Drill open the Ø 13 bran-
ch at the bottom of the tank
with a twist drill (maximum
Ø 9).
2. Push the hose onto the
1.
Fix the DN 50 connec-
tion collars onto the in-
let pipes using the hose
clamps.
2. Attach the connection
collars to the tank inlet
branches with the hose
clamps.
3. Connect the outlet el-
bow to the pressure outlet
of the unit.
4. Install the non-return
valve between elbow and
pressure pipe.
NOTICE! All hose clamp con-
nections must be tightly fit-
ted.
MAINTENANCE
WARNING!
Before you carry out any work on the unit, always pull the mains
plug out of the socket!
The HEBEFIX MINI requires very little maintenance if used
properly and for its intended purpose. Nevertheless, the sys-
tem should be checked at least once a year to ensure that all of
the connections are tightly sealed and to remove any deposits
in the tank.
If the activated carbon filter is used, we recommend that you
change this once a year, or immediately if unpleasant odours
occur.
Clearing blockages in the case of a
malfunction
1. If a hose has been installed for emergency drainage, you can
drain the accumulated water from the tank into a flat con-
tainer and then seal the end of the hose again.
2. Unscrew the cover.
3. Open the maintenance cover, which is now visible.
4. The float switch inside the unit must be clean and able to
move freely. If necessary, clean the inside of the unit and the
suction area below the pump.
5. The ball in the vent must be able to move freely. If necessary,
remove the rubber sealing plug and clean the vent pipe.
6. Reattach both of the lids and carry out a test to make sure
that the system operates properly.
If the malfunction persists, please call customer service.
TECHNICAL DATA
Weight: 3.9 kg
Pressure pipe branch: DN 32
Motor rating: P1 220 W
Voltage: 1/N/PEx230 V
Frequency: 50 Hz
Rated current: 1 A
Housing protection rating: IP 44
Noise level: 70 dB(A)
Pre-fuse: min. 10A (delay)
Type of operation:
• S1: T
55 ̊ C ;
max
• S2: T
70 ̊ C , 3 min;
max
• S3: T
70 ̊ C , 15%
max
Pump performance
H
1
2
3
[m]
Q [m³/h] 4.3 3.9 3.4 2.2 0.5
4
5