5.5
AC/DC Devices
8026844.1K1V/2024-02-08 | SICK
Subject to change without notice
Table 8: Push-pull, PNP, NPN
PNP
Push-pull
NPN
PNP
Push-pull
NPN
U
: 21.6 V ... 253 V AC/DC, Rated insulation voltage U
B
Utilization category: AC-15, DC-13 (EN 60947-1),
CAUTION
Devices produced after 18 Jun 2023, beginning with date code 2325: Provide
suitable arc suppression for inductive or capacitive loads. Relay contacts are
separated from the supply voltage by an isolation of 5 mm.
Devices produced before 18 Jun 2023, with a date code of 2324 and earlier:
Provide suitable arc suppression for inductive or capacitive loads. Relay contacts
are separated from the supply voltage by a basic isolation of 3.2 mm. Depending
on the application, additional isolation might have to be applied in the user's
Circuit.
Table 9: Connection cable and terminal chamber
GLD20x-
1 = BN
2 = BU
3 = WH
4 = BK
5 = GY
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
i
see "Technical data", page 41
xI
1 2
0.32 mm
2
AWG22
O P E R A T I N G I N S T R U C T I O N S | GLD20
OPERATING INSTRUCTIONS
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
250 V, overvoltage category II,
QL
3 4 5
0.4 ... 0.5 Nm
0.14 ... 0.5 mm
2
AWG20 ... 26
< 0.14 mm
2
> 0.5 mm
2