Digital SmartHandle AX Metal frame
Loss of the precise guidance of the handle
It may be difficult to install on mortise locks with a retaining nut.
Do not mechanically alter the locking nut. The handle would then lose
its precise guidance.
Difficult installation due to inaccurate holes
The fitting cannot be installed if the fastening holes and the spindle do not
match.
Make sure that the fastening holes and the spindle are in a vertical line.
NOTE
Effect on the mortise lock
The SmartHandle AX acts exclusively on the latch of the mortise lock.
Locking and insurances
Insurance companies place increased demands on a closure.
1.
If you want to lock the door under insurance law, use a self-locking
panic lock or a locking cylinder in addition to the SmartHandle AX.
2.
Pay attention to the approvals according to EN 179.
SmartHandle AX with self-locking panic lock
The SmartHandle AX only offers full functionality with a self-locking panic
lock.
1.
Combine the SmartHandle AX with a self-locking panic lock.
2.
Pay attention to the declarations of conformity of the lock manufactur-
ers according to EN 179.
Conditions for authorisation security
Operation with Mifare Classic and/or PinCode keypad excludes authorisation
security class D according to DIN EN 16867:2020.
Sealing escutcheon holes
Any escutcheon holes that exist may be used to manipulate the lock.
1.
Seal any escutcheon holes with a blind cylinder, for example.
2.
In the case of FH versions, you must be install a brass dummy cylinder or
locking cylinder.
4. Scope of delivery
SmartHandle AX (metal frame version)
Special tool
Quick guide
For FH version:
Blank cylinder
5. Design
1
6. Prepare door (drilling template)
ü
PH2 screwdriver at hand.
ü
Pin or scriber at hand.
Drill at hand.
ü
Suitable drill bit at hand (Ø 7.2 mm).
ü
Countersink at hand.
ü
1.
Insert the spindle into the mortise lock.
2
2.
Place the drilling template on the spindle.
3
3.
Align the drill template vertically using the printed scale.
4.
Mark the points to be drilled on the door.
4
5.
Remove the drilling template.
5
EN
6.
Remove the spindle.
6
7.
Remove the mortise lock (PH2).
7
8.
Drill the required holes.
8
9.
Countersink the holes with the countersink so that the blind rivet nuts
can be pressed into a flush position later.
9
10. Fit the mortise lock (PH2).
10
7. For door thickness X: prepare spindle
Saw at hand.
ü
Vernier calliper at hand.
ü
ü
PH2 screwdriver at hand.
1.
For X: measure the door thickness.
11
2.
For X: mark the sawing point on the spindle.
NOTE
9 mm spindle with 8 mm end
The 9 mm spindle has an 8 mm end. This end is inserted into the electronic
fitting.
Trim the 9 mm spindle, ensuring that the 8 mm end is not the cut part.
12
3.
For X: trim the spindle with a suitable saw.
13
8. Programming the fitting
Programme the fitting before installation. You can use different
programming devices, depending on the product family.
14
15
16
9. Installing the fitting
ü
Door pre-drilled.
PH2 screwdriver at hand.
ü
TX15 screwdriver at hand.
ü
1.
Insert the supplied blind rivet nuts into the door frame.
17
2.
Screw the mounting plate firmly into place on the outside so that the
spring clips are facing the door (PH2, torque 1.1 Nm).
18
3.
Screw the escutcheon base firmly to the outside (PH2, torque 1.1 Nm).
19
4.
Screw the escutcheon base firmly into place on the inside (PH2, torque
1.1 Nm).
5.
Insert the fitting into the mounts on the mounting plate.
20
6.
Push the fitting into the mounting plate until it locks into position.
21
7.
Screw the fitting firmly to the mounting plate (PH1, torque 0.8 Nm).
22
4. Scope of delivery