ENGLISH
22
Technical Data
Service connection ............................................................................................................................................... 230 V~50 Hz
Motor output S3/ 60% ...................................................................................................................................................1,8 kW
Number o cylinders ...................................................................................................................................................................1
Suction capacity .......................................................................................................................................................... 260 l/min
Free air delivery............................................................................................................................................................ 175 l/min
Max. working pressure .....................................................................................................................................................10 bar
tank capacity ............................................................................................................................................................................ 50 l
Weight ..................................................................................................................................................................................... 31 kg
Degree o protection.......................................................................................................................................................................IP 20
Protection class ........................................................................................................................................................................................1
Sound power level L
*Measured according to 2006/42/EC
service manual. Act responsibly toward third parties.
In case o any doubts about connection and
operation reer please to our customer center
Preserve all the documentation so that anyone who
uses the compressor can consult this beorehand.
Specied Conditions Of Use
The compressor can only be used or the produc-
tion o compressed air to be used at home and by
handymen. – Respecting technical data and saety
precautions.
The compressed air produced by the
compressor cannot not be used or pharmaceuti-
cal, ood or medical purposes or to ll the air
bottles o scuba divers.
The compressor must be used in a suitable
environment (well ventilated with an ambient
temperature o between +5°C and +40°C) and
never in places with dust, acids, vapors, explosive
or ammable gases.
Do not use this product in any other way as stated
or normal use. Not observing general regulations
in orce and instructions rom this manual does not
make the manuacturer liable or damages.
* .......................................................................................................................................................... 97 dB(A)
WA
Read and understand the
operating instructions beore
using the appliance. Abide by all
the saety measures stated in the
Safety instructions
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Insert the plug o the electrical cable in a socket o
suitable shape, voltage and requency complying
with current regulations.
Use extension cables with a maximum length o 5
meters and with a cable cross-section o not less than
1.5 mm2. Use o extension cables o dierent length
and cross-section and also o adapters and multiple
sockets should be avoided.
Check the cable and/or socket or damages beore
the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must
be replaced by the manuacturer. Do not under any
circumstances attempt any repair yoursel.
Never let the compressor come into contact with
water or other liquids and never direct the jet o
liquids sprayed by tools connected to the compressor
towards the compressor: as the appliance is live, this
could cause electrocution or short-circuits.
Never use the appliance with bare eet or wet hands
or eet.
Never yank the power cable to disconnect the plug
rom the power outlet or to move the compressor.
Warning: the compressor may restart when power is
restored ollowing a blackout.