CHARGER/CONTROLLER LED DISPLAY
TABLE II – OPERATING CODE DISPLAYS (LEDS LIGHTED CONTINUOUSLY OR FLASHING)
LED Operating Code Display
SYSTEM ALERT
ALARM SILENCED
PUMP ACTIVITY
AC POWER
=
LED is ON Continuously
NOTICE: All of the situations listed above indicate normal system operation; no action is required.
However, if the BBU pump is running or has run, check the primary pump and actively monitor the
charger status for battery life. Always reset the charger after the pump runs.
During normal system operation, the 'SYSTEM ALERT' LED blinks while the oat switch is on,
indicating the pump should start within 3 seconds. The "AC POWER" LED is lighted
(solid or blinking) as long as the system is plugged in to an operating AC power circuit.
TABLE III – LED FUNCTION DISPLAYS (LEDS LIGHTED CONTINUOUSLY)
CONTROL LED
AC Power
Pump Status
Silenced Audible Alarm
Charging
Battery Status
System Alert
HYD983 (06-08-20)
System Operating Condition
CHARGING
BATTERY STATUS
Indicates
115V AC Power is connected / Unit online
Indicates
115V AC Power is connected / Unit o ine
Indicates
Pump is running (continuous LED)
Indicates
Fast ashing LED: Pump has run
Indicates
Audible alarm is switched off
Indicates
Fast ashing LED: Battery pre-quali cation test is running
Indicates
Battery is charging normally
Indicates
Continuous LED: battery charge is above 20%,
system is maintaining charge
Indicates
Slow ashing LED: battery charge is below 20%
=
LED is Flashing (Fast)
CONTINUOUS ILLUMINATION INDICATES NORMAL OPERATION
AC power is present. Unit is online.
The float switch has been activated. The LED remains on (flashing) after the pump has stopped.
Depress the 'System Test' button to reset it.
Audible Alarm has been silenced. Press and release the 'Silence Alarm' button to reset (activate) the
audible alarm and turn OFF the LED.
Indicates that the battery is charging – see Table II, above.
A. Continuous ON - the battery voltage is above 10.9 Volts DC and capacity is above 20%.
B. Slow Beep/Slow LED Flash - the battery's capacity is below 20%, and voltage is between 8.2VDC
and 10.9VDC.
C. Fast Beep/Fast LED Flash - the battery has been discharged to less than 8.2VDC.
Flashing (in unison with the buzzer) indicates that the charger has entered 'Failure Mode'. Press the
'System Test' and 'Silence Alarm' buttons to reset it.
Note:: If the source of the failure is not corrected, the charger will reenter "Failure Mode". See Table IV
for error code information.
=
LED is Flashing (Slow)
=
LED is OFF
6790 0313
11