6/ USING YOUR WINE CABINET FOR THE FIRST TIME
VIII. Disabling the audible warning signal of the alarms
SET
1
Press the
key for approximately 3 seconds.
3 secs.
SET
2
Select the
alarms pictogram with the
or
keys.
SET
3
Press the
button to confirm.
IX Placing the screen on standby
•
To place the screen on standby, briefly press the
key. Repeat the process to leave standby mode.
•
The cabinet remains in operation when the screen is in standby mode.
It is not possible to activate standby mode whilst the warning light
7/ EVERYDAY MAINTENANCE
Your EuroCave wine cabinet is a tried and tested appliance.
Maintenance tasks about once a year
•
Unplug and unload the appliance.
•
Remove any particles that may block the drainage pipe located
inside the cabinet, at the bottom on the ledge.
•
Clean inside the compartments with water and a gentle
cleaning product.
•
Rinse well. Dry with the EuroCave microfibre cloth, supplied.
•
Glass parts must be cleaned with the non-abrasive microfibre
cloth provided, first dampened with a product suitable for
cleaning glass.
•
Replace the active charcoal filter located in the upper breather
hole of your cabinet (see chapter 6,§ VI). Remove the charcoal
filter manually. It is available from your usual stockist. It must
be replaced by an original manufacturer's part.
•
Check that the door seal is in a good condition. It is often
necessary to clean the seal. Cleaning with unsuitable products
will cause the seals to wear prematurely. You should therefore
observe certain rules: Whenever the seal is cleaned you must
32
afterwards rinse the seal with clean water. No traces of
GB
SET
4
keys, select "On" to activate
With the
or
and "Off" to disable the audible warning signal of
the alarms.
SET
5
Press the
button to confirm.
Disabling the audible warning signal of the alarms does not
disable the visual alarms.
remains on.
cleaning product must remain on the seal. EuroCave
recommends only using a mild soapy solution. If cleaning with
this type of solution proves insufficient, it is possible to
ocasionally use an ethanol-based solution, but with a
concentration of less than 10%, and taking care to rinse the
seal well with clean water.
•
Carefully vacuum the lower and upper ventilation strips of
your cabinet
•
Clean the light strip using the microfibre cloth supplied. Never
use alcohol-based detergents.
•
To remove text written using the white marker pen on our
bottle identification labels, use a damp cloth.
•
To clean the fronts of the shelves:
- use the microfibre cloth provided
- only use water or a glass cleaning product
•
To clean the glass or plastic parts of your cabinet, use the
EuroCave microfibre cloth.
•
Grease can appear on the hinge. It can occur in standard
conditions. We suggest to wipe it out with a towel.
7/ EVERYDAY MAINTENANCE
Never use a cleaning product containing acetone, petrol, alcohol, white spirit or synthetic thinners which will damage the front.
Caring for stainless steel:
To clean stainless steel surfaces, we recommend that you use water and
•
a mild liquid soap.
Ensure that the soap does not contain grains which could scratch the
•
surface.
The solution must be applied with a soft cloth.
•
Do not pour liquid directly onto the stainless steel. Likewise, never use solvents, harsh, granular or abrasive products, petrol or alcohol which
could damage the surface of your cabinet. No chlorine-based products.
Cleaning the condenser every two years (contact your EuroCave
retailer/customer service):
Remove the appliance from the kitchen unit in order to gain access to
•
the condenser, located at the back of the cabinet (see steps 1 - 6,
Chapter 4, § III).
Unload and unplug the appliance.
•
Unscrew the 2 rear steel plates using a T25 Torx screwdriver.
•
Carefully vacuum the condenser in order to remove any dust that may
•
have accumulated.
Carefully screw back on the two rear steel plates using a T25 Torx
•
screwdriver, to prevent vibration.
8/ OPERATING FAULTS
Possible incidents
Causes
The temperature display flashes
"LO" or "HI" alternately with the
The temperature has
temperature
been 4 °C lower or
higher than the selected
temperature, for at
The temperature display is still
least 24 hrs.
flashing "LO" or "HI" after having
carried out the above correct action
The door has been
The
and
pictograms are
open for more than
flashing
5 minutes
The relative humidity
The
pictograms are
level has been < 50%
and
for more than 96 hrs
flashing
The humidity level is above the
desired value
Charcoal filter alarm
The
pictogram is displaying
" Er1 " is flashing on the temperature
Temperature sensor
display.
fault warning
The cabinet will not switch on
" Erh " is flashing on the humidity
Humidity sensor fault
display
alarm
The cloth used must not have buttons or zips, which could scratch the
•
stainless steel.
Rub the surface, following the direction of the stainless steel brushing.
•
Dry the surface with a clean soft cloth following the direction of
•
brushing.
Return the appliance to its location.
•
Put the bottles back in the cabinet.
•
Corrective action
Check that the door is closed.
Check the condition of the door seal.
If you have loaded your cabinet with a large amount of bottles in the last
few hours, wait a while then check again. If the alarm persists, contact your
EuroCave stockist.
If the problem persists, unplug the cabinet and contact your EuroCave stockist.
Ensure that the door is closed properly.
(see chapter 6, § IV).
•
Pour a glass of water into the channel in the tray
•
In order to know how often to add water, count the number of days
separating the 1st day you added water and the day the pictogram was
displayed.
After a few hours, the pictogram goes out.
•
Empty the cabinet, remove the humidity cartridge and clean the tray.
Contact your EuroCave stockist if the problem persists in spite of you having
carried out these different actions.
Replace the charcoal filter and reset the meter. (See chapter 6, § VI).
Unplug and then plug back in your appliance. (Steps 1 - 6, Chapter 4 § III)
If the problem persists, contact your EuroCave customer service department/
stockist.
Unplug and then plug back in your appliance. (Steps 1 - 6, Chapter 4 § III)
If the problem persists, contact your EuroCave customer service department/
stockist.
Unplug and then plug back in your appliance. (Steps 1 - 6, Chapter 4 § III) If
the problem persists, contact your EuroCave customer service department/
stockist.
33
GB