INSTALLATION
No extra modifications for ventilation need be made where there is a fixed
panel.
Ventilationprotection
The electronics in the appliance require cooling. The cool air is sucked from
behind the cupboard and blown out at the front and at the bottom in the
front of the appliance. The hob can only operate if there is sufficient
circulation of fresh air. The appliance will switch off after a short time if
there is not enough circulation. See to it that the traverse lath does not
hinder the airflow.
Plane or saw the lath oblique if necessary.
Above a 60 cm oven of the ATAG brand
Recess height minimum 600 mm. Ventilation is via plinth and rear of
oven. Where there is a oven, a gap of at least 560 x 6 mm should be
made at the front. Cut out ventilation openings "A" + "B" (100 cm
Make an opening in the side wall "C" of the kitchen cupboard for
leading the connection cable through. The hob may only be combined
with ATAG ovens, not with combi-microwave ovens.
136
building in
C
600
B
A
INSTALLATION
Installation of the induction hob above a combimicrowave oven, a 90 cm
ATAG oven or an oven of a different brand
).
2
Ensure that the connection cables hang freely. If there is a drawer
underneath the hob, make sure that the contents do not project above
the edge of the drawer and interfere with the ventilation.
Saw out the ventilation opening(s), making sure that the total surface of the
holes is a minimum of 100 cm
. See the drawing, for example, showing
2
2 holes.
2
50 cm
e
t
e
r
Fit a protective plate between the oven and the hob. The plate should be
at least 10 mm thick and heat-resistant (85 °C). The space between the
underside of the hob and the protective plate must be at least 50 mm.
t
e
r
To protect the air flow, fit a protective panel - of the same material as the
protective plate - between the protective plate and the hob. Ventilation is
via the adjoining cupboards.
building in
137