Télécharger Imprimer la page

Atag HI6071T Notice D'utilisation page 68

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately
(see table). Also saw out any partitions that may be present. The distance
from the saw line to the rear wall and/or side wall is indicated in the
table.
48
min.50
Table
Type of hob
Appliance width x depth
Installation height from top of worktop
Cut out dimensions width x depth
Distance from saw line to rear wall
Distance from saw line to side wall
Space to be left free around the appliance
cabinet
min. 650 mm
min. 450 mm
min. 40 mm
134
building in
604
512
560
490
HI6071T
604 x 512 mm
48 mm
560 x 490 mm
Minimaal 50 mm
Minimaal 50 mm
cooker hood
min. 600 mm
min. 40 mm
side wall
Ceramic hob
INSTALLATION
Ventilation
De elektronica in het toestel heeft kThe electronics in the appliance
require cooling. The ventilation openings are located on the underside of
the appliance. It must be possible for cool air to be drawn in through
these openings. The appliance is fitted with outlet openings at the front
and bottom. The kitchen unit will require a few modifications to allow
optimum cooling of the hob.
Above drawer or fixed panel
Saw out the ventilation openings (min. 100 cm
and rear of cupboard.
Do not allow the ventilation openings on the underside of the appliance
to be blocked by a drawer. Where there is a drawer, a gap of at least
560 x 6 mm should be made at the front. The distance between drawer A
and the hob should be a minimum of 10 mm.
min.
10 mm
min.
560 x 6 mm
150
building in
2
). Ventilation is via plinth
A
135

Publicité