Troubleshooting Guide - Hatco GLOMAX GM5AH Série Instructions Originales

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
WARNING
This unit must be serviced by qualified personnel only.
Service by unqualified personnel may lead to electric
shock or burn.
Symptom
Unit is turned "On" but there is
no heat.
Heat on but no lights (GM5AHL
only).
Heat is inadequate.
Heat is excessive.
Control switches burn out.
Troubleshooting Questions?
If you continue to have problems resolving an issue, please contact the nearest Authorized Hatco Service Agency or Hatco for
assistance. To locate the nearest Service Agency, log onto the Hatco website at www.hatcocorp.com, select the Support pull-
down menu, and click on "Find A Service Agent"; or contact the Hatco Parts and Service Team at:
Telephone: +1-414-671-6350
e-mail: support@hatcocorp.com
Form No. GM5AHCEM-0619
Probable Cause
No power to unit.
Switch is defective.
Wiring is open.
Heating element defective.
LED assembly defective.
Faulty wiring.
Unit mounted too high above target area.
Excessive air movement around strip heater
target area.
Incorrect power supply (low).
Unit mounted too close to target area.
Voltage supply too high.
Remote control box is mounted too close to
the heat zone.
Switches used are not Hatco supplied.

TROUBLESHOOTING GUIDE

ELECTRIC SHOCK HAZARD: Turn OFF power switch, turn
off power at circuit breaker, and allow unit to cool before
performing any cleaning, adjustments, or maintenance.
Check circuit breaker and reset as necessary.
Contact Authorized Service Agent or Hatco for assistance.
Contact Authorized Service Agent or Hatco for assistance.
Lower unit, putting effective heat closer to target.
Restrict or redirect air movement (air conditioning duct or
exhaust fan) away from unit.
Check power supply to unit, making sure it matches rating on
the unit. If power supply is incorrect, change to match rating
on unit.
Check to see that installation is within specifications for type/
model. Increase mounting height if too close.
Check power supply to unit, making sure it matches rating on
unit. If power supply is incorrect, change to match rating.
Move remote control box away from the heat zone. The
maximum ambient temperature allowed for the control box is
40°C (104°F).
Genuine Hatco Parts are specified to operate safely and
properly in the environment in which they are used. Contact
Authorized Service Agent or Hatco to replace switches with
Genuine Hatco Replacement Parts.
11