Abicor Binzel ABIPLAS CUT 200 W Mode D'emploi page 43

Torche de coupage plasma
Masquer les pouces Voir aussi pour ABIPLAS CUT 200 W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

®
ABIPLAS
CUT 200 W/MT
Fault
Cutting nozzle burned
out
Strong electrode burn-out • Pressure drop while cutting due to
Tab. 10
Troubleshooting
11 Disposal
NOTICE
• Do not dispose of the device with household waste.
• For disposal, observe the local regulations, laws, provisions, standards and guidelines.
BAL.0120 • 2021-08-20
Cause
• Damaged or loose nozzle
• Contact with the workpiece
• Start of cut at the edge of the
workpiece too fast
• Too much spatter when punching
holes
• Pilot arc struck too long and too
frequently in the air
• Pilot arc too strong (depends on
the power source)
incorrectly set pressure monitor
• Loose electrode
• Pilot arc struck too long and too
frequently in the air
Troubleshooting
• Hand-tighten the nozzle or
protective cap. Replace the nozzle
if necessary
• Avoid contact
• Start cutting at a lower rate
• Start at as great an angle as
possible and slowly insert
• Shorten/avoid ignitions in the air if
possible
• Set the pilot arc current to the
lowest possible value
• Correct the pressure monitor
setting
• Hand-tighten the electrode
• Shorten/avoid ignitions in the air if
possible
11 Disposal
EN - 21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Abiplas cut 200 w mt

Table des Matières