Abicor Binzel ABIPLAS CUT 200 W Mode D'emploi page 37

Torche de coupage plasma
Masquer les pouces Voir aussi pour ABIPLAS CUT 200 W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

®
ABIPLAS
CUT 200 W/MT
6.3.3 Plasma cutting torch with a central connector
The plasma cutting torches with a central connector must only be connected to power sources
with central sockets which comply with the safety requirements established in EN 60974-1 and
EN 60974-7.
.
NOTICE
• The assignment of the cutting torch and cutting power source is clearly defined by the
codes on the plug and the socket and must be observed under all circumstances.
7 Operation
DANGER
Shortness of breath and poisoning caused by inhaling phosgene gas
When welding workpieces that have been degreased with chlorinated solvents, phosgene
gas is formed.
• Do not inhale fumes and vapours.
• Ensure a sufficient supply of fresh air.
• Rinse workpieces with clean water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the welding area.
DANGER
Risk of burns
During welding activities, sparks, glowing workpieces or hot slag can produce flames.
• Check the work area for flashpoints.
• Provide suitable fire extinguishing equipment at the workstation.
• Allow workpieces to cool down after welding.
• Prior to performing welding work, properly fasten the ground clamp to the workpiece or
the welding table.
WARNING
Arc eye
The arc produced by welding can damage the eyes.
• Check and wear your personal protective equipment.
NOTICE
• Ensure that all required parameters have been set.
• Check the actual gas flow on the measuring instruments or by closing and opening the
corresponding gas outlet openings on the torch.
BAL.0120 • 2021-08-20
7 Operation
EN - 15