2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Detection Start Angle (Select From Graph)
[Functional overview]
Unless the accumulated tightening angle reaches this value, snug point detection does
not start.
This parameter is enabled only when the snug point setting is "Select From Graph."
[Default value]
[Setting value]
0° to 99999°
Snug Point Detection Level
[Functional overview]
This setting changes the load level for bolt snug point detection.
Increasing the snug point detection level can prevent the tool from stopping before a
bolt reaches the snug point because of a high load during tightening.
(Depending on the work, even if the snug point detection level is increased, the tool
might stop before the snug point.)
[Default value]
*0
[Setting value]
*0 to 7
Disable Reverse
[Functional overview]
When this function is ON, the tool will not operate reversely even if the trigger is on.
[Default value]
OFF
[Setting value]
ON, OFF
Entering the value with (*) will disable the function.