2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Angle Before Snug Upper Limit
[Functional overview]
Set the upper limit of accumulated angle, from trigger-on to snug point, for judging work
OK or NOK.
The snug point detection method can be selected from snug point setting.
[Default value]
*99999°
[Setting value]
0° to *99999°
Angle Before Snug Lower Limit
[Functional overview]
Set the lower limit of accumulated angle, from trigger-on to snug point, for judging work
OK or NOK.
The snug point detection method can be selected from snug point setting.
[Default value]
*0°
[Setting value]
*0° to 99999°
Angle After Snug Upper Limit
[Functional overview]
Set the upper limit of accumulated angle, from snug point to running stop, for judging
work OK or NOK.
The snug point detection method can be selected from snug point setting.
[Default value]
*9999°
[Setting value]
0° to *9999°
Angle After Snug Lower Limit
[Functional overview]
Set the lower limit of accumulated angle, from snug point to running stop, for judging
work OK or NOK.
The snug point detection method can be selected from snug point setting.
[Default value]
*0°
[Setting value]
*0° to 9999°
Entering the value with (*) will disable the function.