2.2.8 CONFIGURING PARAMETERS OF THE TOOL
(6) Set a Snug Point Detection Level
The snug point detection level setting is used in the following cases.
Torque
Torque
setting
7
6
5
4
3
2
Load generated halfway
Load generated halfway
1
Can be set in 7 levels
EN
The load generated
halfway due to
painting or tapping
screws is not detected
as a snug point.
When "1" is set, it will be detected as a
snug point, resulting in a halfway stop.
When "2" or higher is set, it will not be
detected as a snug point.
7:Set for the work with a high load generated halfway
1:Set for the work with a low load generated halfway
0:Snug point detection level function OFF
Load generated halfway
Load generated halfway
When "4" or lower is set, it will be detected
as a snug point, resulting in a halfway stop.
When "5" or higher is set, it will not be
detected as a snug point.