Battery Size / Rating
Small batteries
Motorcycle, garden tractor, etc.
Cars and Trucks
Marine / Deep-cycle
14. DISPLAY MESSAGES
SELECT BATTERY TYPE (No LED lit) – Waiting for user to select battery type.
CONNECT CLAMPS TO LITHIUM ION BATTERY (No LED lit) – Plugged into the AC
outlet, and lithium-ion battery type is selected, without the clamps connected to a battery.
LITHIUM ION BATTERY-PRESS AGAIN FOR LEAD ACID (No LED lit) –Charging will
begin for lithium-ion battery type. Press again to change to lead-acid battery type.
CONNECT CLAMPS TO LEAD-ACID BATTERY (No LED lit) – Plugged into the AC outlet,
and lead-acid battery type is selected, without the clamps connected to a battery.
LEAD-ACID BATTERY-PRESS AGAIN FOR LITHIUM ION (No LED lit) – Charging will
begin for lead-acid battery type. Press again to change to lithium ion battery type.
WARNING-CLAMPS REVERSED (No LED lit) – Plugged into the AC outlet and the
clamps are connected backwards to a 12V battery.
ANALYZING BATTERY (Green LED lit) – Plugged into the AC outlet, and when first
correctly connected to a battery.
CHARGING – xx% (Green LED lit) – Plugged into the AC outlet and correctly connected to
a discharged battery.
FULLY CHARGED-AUTO MAINTAINING (Green LED pulsing) – Plugged into the AC
outlet and correctly connected to a fully charged battery.
CHARGE ABORTED-BAD BATTERY (Green LED flashing) –
Circumstances that could cause an Abort situation during charging:
• The battery is severely sulfated or has a shorted cell and can't reach a full charge.
• The battery is too large or there is a bank of batteries and it doesn't reach full charge
within a set time period.
Circumstances that could cause an Abort situation during maintain:
• The battery is severely sulfated or has a weak cell and will not hold a charge.
• There is a large draw on the battery and the charger has to supply its maximum maintain
current for a 12 hour period to keep the battery at full charge.
BATTERY DISCONNECTED (No LED lit) – After charging has begun, the charger has lost
its connection to the battery.
15. MAINTENANCE INSTRUCTIONS
15.1 Cleaning and user maintenance should not be done by children without supervision.
15.2 After use and before performing maintenance, unplug and disconnect the battery charger
(see sections 6, 7 and 8).
15.3 Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery
connectors, cords, and the charger case.
200-315 CCA
315-550 CCA
550-1000 CCA
•
10
6-12 Ah
12-32 Ah
36-46 Ah
46-58 Ah
58-111 Ah
56 Ah
86 Ah
96 Ah
106 Ah
•
Charge rate /
Charging time (3 A)
1
/
- 2
/
h
1
1
2
2
2
/
- 7 h
1
2
7
/
- 9
/
h
1
1
2
2
9
/
- 12 h
1
2
Maintain only
Maintain only
Maintain only
Maintain only
Maintain only