Technical data
Type
Outdoor
Heatpanel 1800
Power
Voltage
IP class
Front
Backside
Dimensions
114,5x17,2x4,5
Weight
Safety Warnings
Warnings for installation
1. In the event of incorrect usage or installation, there is a risk of
electric shocks and/or a fire hazard.
The casing, particularly the front of the device, will get extremely
2.
hot, up to 360°C. For safety reasons, the lowest point of the
Outdoor heat panel must always remain at least 180 cm above the
ground, whether secured to the wall or ceiling.
3. The ceiling or the wall to which the device is mounted must not be
made of flammable materials. It must be resistant to temperatures
of at least 150°C without burning, melting, deforming or bursting
into flames. Check regularly to ensure that the surface is not
overheating; this could be dangerous!
For ceiling mounting: maintain a minimum distance to all side walls
of 100 cm.
For wall mounting: maintain a minimum distance to all side walls
and ceilings of 20 cm.
4. Before use, check to ensure that the voltage, as indicated on the
device, corresponds with the voltage from the electrical point to
which it will be connected. The power supply and connection must
fulfil the valid, legal standards and national regulations. Only use an
undamaged, earthed socket that is protected with a 30 mA earth
leakage circuit breaker.
5. When you are using the unit outside, it must be connected to a
suitable, waterproof, earthed socket. All electrical connections must
Outdoor
Heatpanel
1800 (RC)
1800 Watt
steel
114,8x20x4,8
cm
9,2 kg
Outdoor
Heatpanel
2400 (RC)
1800 Watt
220/240V~50Hz
IPX4
Aluminium
Aluminium
144,5x20x4,8
cm
6,8 kg
35
Outdoor
Heatpanel
3200 (RC)
2400 Watt
Aluminium
148,5x20x4,8
cm
8,2 kg
3200 Watt
Aluminium
cm
10,5 kg