PRELIMINARI - PRE-INSTALLATION INFORMATION - PRÉALABLES - VORBEREITUNG -
PRELIMINARES - ПРЕДВАРИТЕЛЬНАЯ ПОДГОТОВКА - ΠΡΟΕΡΓΑΣΙΕΣ - 引言
Attention!
If the cooling circuit is damaged:
Remove the mains connector.
Ventilate the area where the unit is located for a few minutes.
Contact the technical support service.
Leaking refrigerant can cause eye injuries because it is pressurised.
R600a refrigerant is a natural gas with high environmental compatibility, but it is flammable.
It does not damage the ozone layer and it does not increase the greenhouse effect.
Technical data:
CEE 7/4 type plug (Schuko) with protection fuse
Voltage supply: 220-240 VAC - 50 Hz
Max. power consumption: 230 W
Protection type: IPX1
Relative atmospheric humidity: max. 95%
Ambient temperature: min. 5°C - max. 32°C (Class N)
Refrigerant: 0.016 Kg - R600a
Maximum CO2 inlet pressure from external line: 5 Bar [0.5 MPa]
WLAN: 2.4 GHz, IEEE 802.11 b/g/n
Bluetooth: v4.2 BLE
Wi-Fi coverage variable depending on the materials and walls between the transmitter and the receiver
Empty weight: approx. 20 Kg
Full weight: approx. 23 Kg
Technical/health data:
All the water dispensed by the unit is filtered
Available waters: 3 levels of sparkling water, chilled, fresh and cold
Continuous dispensing is electronically stopped for safety reasons at the following values:
- Still (room temp/Mix) 5 litres (or 3 minutes)
- Max, min and cold sparkling 3 litres (or 2 minutes)
- Medium sparkling 1.5 litres (or 1 minute)
Hydraulic pressure: min. 2 Bar [0.2 MPa] - max. 5 Bar [0.5 MPa] - recommended 3 Bar [0.3 MPa]
Water temperature at unit inlet: max. 30°C
Temperature of chilled water: approx. 5 – 10°C
Activated carbon filter: filter capacity 1500 l or max 1 year of use (recommended after 6 months)
CO2 Bypass available for connection to external cylinder
Management/Display of the status of consumables via local digital display
In the event that the product is not to be used:
- for 2 days: rinse with at least 3 litres of water spread over the various waters available
- for 4 weeks or more: replace the filter cartridge and sanitise the system using the specially designed kit that
can be ordered via the dedicated channels.