Télécharger Imprimer la page

Miller I-24A CE Manuel Du Propriétaire page 19

Masquer les pouces Voir aussi pour I-24A CE:

Publicité

5-4. 14-Pin Receptacle Information
J
A
K
I
B
N
L
C
H
M
D
G
E
F
*The remaining pins are not used.
5-5. Connecting Welding Gun And Weld Cable
Tools Needed:
9/16, 5/8 in.
Pin*
A
24 volts AC with respect to pin G.
B
Contact closure to A completes 24 volts AC contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts DC output to remote control with respect to pin D.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from remote control with respect to pin D.
F
Current feedback; 0 to 10 volts DC, 1 V/100 A
H
Voltage feedback; 0 to 10 volts DC, 1 V/10 arc volts
1
4
3
Pin Information
2
Ref. S-0004-A
1
Gun/Feeder Adapter
2
Gun Connector
Insert gun connector into adapter.
Tighten locking ring.
3
Weld Cable Terminal
4
Weld Cable From Welding
Power Source
801 922-D
OM-186895 Page 15

Publicité