English
3
Machine description
3.7
Chemicals
Operate the warewasher with chemicals from Miele. Contact Miele or an authorised customer service team before using other chemic-
als. Only use products that are suitable for commercial warewashers.
Rinse aid
Rinse aid is required in order to ensure that water on the wash items runs off as a thin film after washing. This ensures that the wash
items dry quickly.
Rinse aid is automatically dispensed using an integrated dosing device.
Detergent
A detergent is required to dissolve food residues and dirt on the wash items. Detergent is automatically dispensed using an integrated
or external dosing device.
To avoid damaging the warewasher and to achieve a good wash result:
– Do not use acidic detergents.
– Do not use foaming products (e.g. manual washing-up liquid) for pre-treating the wash items.
3.8
Suction tube with level control
Note: Only for machine with external canisters.
The float switch (1) can detect a defect in the chemicals and indicates this on the display (} page 68).
3.9
Technical data
Description
Rack dimensions
Tank capacity
Noise emission
IP protection class
Min. water flow pressure
Max. inlet pressure
(back pressure)
Flow rate
Inlet water temperature
Exhaust air
Observe local guidelines, e.g. DIN EN 16282 / VDI guideline 2052 when constructing the ventilation system.
Operating conditions
Name
Temperature at the installation site
Relative air humidity at the installation site
Storage temperature
Max. height of the installation location above sea level
Test marks and symbols
CE
2006/42/EC Machine Directive
UKCA
The Supply of Machinery (Safety) Regulations 2008
48
Note
Standard
dB(A)
PTD AE RO
Plastic rear cover
Stainless steel rear
panel
Standard
kPa (bar)
PTD AE RO
kPa (bar)
l/min
Standard
PTD AE RO
Colour
(cover cap)
Blue
Grey
1
Unit
PTD 701
mm
400 x400
l
9,5
°C
Unit
°C
%
°C
m
|
|
12623590; 2024-01
Canister
Rinse aid (optional)
Detergent (optional)
Value
PTD 702
PTD 703
500 x 500
500 x 500
15,3
55
62,5
IPX3
IPX5
100 (1,0)
140 (1,4)
1000 (10,0)
min. 4
max. 60
max. 35
Value
0 - 40
< 95
> -25
2000
Operating instructions
PTD 704
500 x 500
500 x 540
-