INSTALLATION OF THE CONDENSATE DISCHARGE TUBE
1.Orient the condensate discharge tube downwards to
ensure a correct discharge of condensate.
2.Do not bend or twist the condensate discharge tube
in order to avoid potential obstructions; do not
submerge the end of the pipe directly in water (fig.3).
CONNECTING THE COOLANT PIPE
1.Remove the cover protecting the pipe from the side panel (on the right or left hand side, according to the direction
in which the pipe itself extends) (fig. 4).
2.Notify the customer that the cover must be kept, for possible reuse in the event of the internal unit being moved
to another position.
3.Lay the pipe as shown in the figure. Bend the connection pipe, making sure that it is not more than 43 mm from
the wall (fig. 5).
4.Fix the end of the pipe as shown in the relevant paragraph.
Pipe holder
PIPE SUPPORT
Pipe Cover
RIGHT COVER
(right)
Right piping
RIGHT
PIPE
FITTING THE INTERNAL UNIT
1.Pass the pipe through the opening made in the wall.
2.Connect the upper part of the unit to the metal plate as shown in fig. 6, then move it to right and left to check it
is firmly fixed.
3.Insert a spacer made of soft material between the
unit and the wall, so that the machine remains
partially raised and laying of the pipe is thus made
easier (fig. 7). This spacer will be removed when
the operation has been completed.
4.Push the lower part of the unit against the wall,
and then move the unit from right to left and up
and down, to check it is firmly fixed.
5.Wrap the copper pipes, the electrical cables and
the condensation drainage pipe together with
insulating tape, taking care to ensure that the
drainage pipe is as low as possible so as to
facilitate drainage. When the unit is operating in
cooling mode, condensation collects in it inside a tank, from which the drainage pipe starts. Make sure that this
tank is free and does not contain waste materials (fig. 8).
Pipe Cover (left)
LEFT COVER
Left piping
Left back piping
LEFT REAR PIPE
Right back piping
RIGHT REAR PIPE
fig.4
Indoor unit outline
OUTLINE OF INTERNAL UNIT
LEFT
PIPE
fig.3
Connective pipe
PIPE
.
fig.5
UPPER
Upper Hook
HOOK
Lower Hook
LOWER
HOOK
fig.6
23