INSTALLATION OF THE INTERNAL UNIT
INSTALLATION OF THE WALL-MOUNTED PLATE
1.To guarantee proper drainage of condensation, position the plate in such a way that it is perfectly horizontal and
surrounded by free space, making sure it is pointing as shown in
fig. 1a.
2.Drill 8 holes with a diameter of 5 mm in the wall, and insert the
expansion plugs supplied.
3.Fit the plate and lock it using the 8 screws type "A" size 3.9 x 25
mm.
Indoor unit outline
OUTLINE OF INTERNAL UNIT
>= 120 MM
120mm or more
FROM WALL
to wall
LEFT HOLE
Left refrigerant
FOR PIPES (Ø 65)
pipe hole
65
7 ÷ 12
(A: 710(<12000Btu/h model); B:790(12000Btu/h model)
Indoor unit outline
OUTLINE OF INTERNAL UNIT
>= 120 MM
120mm or more
FROM WALL
to wall
LEFT HOLE
Left refrigerant
FOR PIPES (Ø 65)
pipe hole
65
18
OUTLINE OF INTERNAL UNIT
HANGED PART
Hooked Part
>= 120 MM
Above 120mm from
FROM WALL
the wall
LEFTHOLE FOR
115
PIPES (Ø 95)
Pipe hole
24
INTERNAL
Indoor
fig.2
22
150mm or more to ceiling
>= 150 MM FROM CEILING
A , B
7H-9H A= 710 mm
12H
A= 790 mm
fig.1b
>= 150 MM FROM CEILING
150mm or more to ceiling
920
( 12000Btu/h model)
A= 920 mm
fig.1c
Above 150 from the ceiling
>= 150 MM FROM CEILING
Hooked Part
HANGED PART
1080
432
A
465
A= 1080 mm
Indoor Unit Outline
fig.1d
EXTERNAL
Outdoor
Installation plate
PLATE
>= 120 MM
120mm or more
FROM WALL
to wall
RIGHT HOLE
Right refrigerant
FOR PIPES (Ø 65)
pipe hole
Installation plate
PLATE
>= 120 MM
120mm or more
FROM WALL
to wall
RIGHT HOLE
Right refrigerant
FOR PIPES (Ø 65)
pipe hole
HANGED PART
Hooked Part
108
432
>= 120 MM
Above 120mm from
FROM WALL
the wall
LEFT HOLE FOR
115
PIPES (Ø 95)
465
Pipe hole
fig.1a
4.Drill the wall to allow passage
of the pipes and electrical
connections (diam. 65 mm, 95
mm mod.24) (fig.1b,1c,1d).
The hole housing the drainage
pipe must be inclined towards
the exterior, with the outlet
section at a height 5-10 mm
lower than the inlet section, so
as to encourage drainage of
65
condensation (fig. 2).
4.Make sure that the plate is
firmly fixed; each screw should
be capable of supporting a
breaking load of at least 60 kg.
65