Télécharger Imprimer la page

Pelgrim IDK564 Notice D'utilisation page 108

Masquer les pouces Voir aussi pour IDK564:

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
Electrical connection
1. blue
2. brown
3. grey
4. black
5. yellow/green
EN 24
The appliance is delivered with a connection cable. As standard, the
connection cable has a connection between the brown and blue wires
and between the grey and black wires. In most cases you should
remove these connections.
1
2
N
L
230V
2 phase connection
2 line + 2 neutral 2 2N a.c. 230 V
Remove the connections.
The fuse box in your home must be fitted with a 16 A fuse.
1
2
N1
N2
L1
L2
230V
230V
1. neutral connection N1 (blue)
2. neutral connection N2 (brown)
3. line connection L1 ( grey)
4. line connection L2 ( black)
3
4
5
3
4
5

Publicité