Télécharger Imprimer la page

DAB MCE-30/C Instructions Pour L'installation Et La Maintenance page 23

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 40
Use is allowed only if the electric system is in possession of safety precautions in accordance with the regulations in force in the country
where the product is installed (for Italy CEI 64/2). The appliance is not intended to be used by persons (including children) with reduced
physical, sensory or mental capacities, or who lack experience or knowledge, unless, through the mediation of a person responsible
for their safety, they have had the benefit of supervision or of instructions on the use of the appliance. Children must be supervised to
ensure that they do not play with the appliance.
2.2
Responsibility
The Manufacturer does not vouch for correct operation of the machine or for any damage that it may cause if it has been tampered
with, modified and/or run outside the recommended work range or in contrast with other indications given in this manual.
2.3
Particular warnings
Always switch off the mains power supply before working on the electrical or mechanical part of the system. Before opening
the equipment, wait at least 15 minutes after disconnecting it from the power supply. The capacitor of the direct current
intermediate circuit remains charged with dangerously high voltage even after the mains power has been turned off.
The MCE/C is cooled by the motor cooling air, therefore it is necessary to make sure that the motor's cooling
system is in good working condition.
Mains terminals and motor terminals may still have dangerous voltage when the motor is stopped.
3.
APPLICATIONS
The inverter of the MCE/C series is a device conceived for the management of circulation pumps allowing integrated regulation of the
differential pressure (head); it is thus possible to adapt the performance of the circulation pump to the actual demands of the system.
This determines considerable energy saving, a greater possibility of control of the system, and reduced noise.
The MCE-C inverter is designed so that it can be housed directly on the pump motor body.
4.
TECHNICAL DATA
Voltage [VAC] (Tol. +10/-20%)
Phases
Inverter power
Frequency [zH]
supply
Current [A]
Leakage current to earth [mA]
Voltage [VAC] (Tol. +10/-20%)
Phases
Inverter output
Frequency [Hz]
Current [A rms]
Mechanical power P2
Mechanical
Unit weight [kg] (excluding packaging)
specifications
Maximum dimensions [mm] (WxHxD)
Voltage [VAC] (Tol. +10/-20%)
Phases
Inverter power
Frequency [zH]
supply
Current [A]
Leakage current to earth [mA]
Voltage [VAC] (Tol. +10/-20%)
Phases
Inverter output
Frequency [Hz]
Current [A rms]
Mechanical power P2
Mechanical
Unit weight [kg] (excluding packaging)
specifications
Maximum dimensions [mm] (WxHxD)
Voltage [VAC] (Tol. +10/-20%)
Phases
Inverter power
Frequency [zH]
supply
Current [A]
Leakage current to earth [mA]
Inverter output
Voltage [VAC] (Tol. +10/-20%)
ENGLISH
MCE-22/C
220-240
1
50/60
22,0
0 - V supply
3
0-200
10,5
3 HP / 2.2 kW
MCE-55/C
380-480
3
50/60
17,0-13,0
0 - V alim.
3
0-200
13,5
7,5 CV / 5,5 kW
MCE-150/C
380-480
3
50/60
42,0-33,5
0 - V alim.
20
MCE-15/C
MCE-11/C
220-240
220-240
1
50/60
50/60
18,7
12,0
< 2
0 - V supply
0 - V supply
3
0-200
0-200
8,0
6,5
2 HP / 1.5 kW
1.5 HP / 1.1 kW
5
200x199x262
MCE-30/C
380-480
3
50/60
11,5-9,0
< 4
0 - V alim.
3
0-200
7,5
4,0 CV / 3 kW
7.6
270x355x195
MCE-110/C
380-480
3
50/60
32,5-26,0
< 10
0 - V alim.
1
3

Publicité

loading

Ce manuel est également adapté pour:

Mce-15/cMce-11/cMce-55/cMce-22/cMce-150/cMce-110/c