7.4. Electrical connection of the
device socket
WARNING!
Risk of injury due to electrical shock!
• Before reaching into the system, switch off the electrical
power supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety
regulations for electrical equipment!
If the protective conductor contact between the coil and
housing is missing, there is danger of electrical shock!
• Always connect protective conductor.
• Check electrical continuity between coil and housing.
Seal
Authorized device socket
e.g. Type 2508 in accordance with
DIN ISO 175301-803 Form A
Fig. 2:
Electrical connection of the device socket
english
16
7.5. Manual control
To control the valve manually, the hand lever under the coil
must be turned into the vertical position.
NOTE!
Caution!
• Do not overturn hand lever!
• When the hand lever is actuated, the valve can no longer
be switched electrically.
Hand lever
Fig. 3:
Manual control
english
18
max. 1 Nm
Opened position
Closed position
Pulse version (optional, Code CF 16):
• Valve opens when current pulse
min. 50 ms:
- on Pin 1, + on Pin 2
• Valve closes when current pulse
min. 50 ms:
+ on Pin 1, - on Pin 2
Note the voltage and current type as specified on
the type label.
→
Tighten device socket (for permitted types see data
sheet), observing max. torque of 1 Nm.
→
Check that seal is fitted correctly.
→
Connect protective conductor and check electrical con-
tinuity between coil and housing.
8.
MAINTENANCE,
TROUBLESHOOTING
8.1. Safety instructions
DANGER!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the pres-
sure and vent the lines.
Risk of injury due to electrical shock!
• Before reaching into the system , switch off the power
supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety
regulations for electrical equipment!
WARNING!
Risk of injury from improper maintenance!
• Maintenance may only be carried out by authorized
technicians with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following maintenance, ensure a controlled restart.
Type 6213 EV / 6281 EV
1
2
english
17
english