Milltronics Easy Aimer - 2
The Easy Aimer is an accessory device for aiming Siemens Milltronics ultrasonic
transducers used in process material level measurement.
178 mm
(7")
Assembly
1.
Feed the transducer cable through the supplied coupling and conduit. Then
assemble the transducer, coupling, and conduit as shown. If the transducer
diameter is greater than 148 mm (5.8"), use the customer supplied mounting plate. If
sealing is required, include the customer supplied gasket.
2.
Feed the conduit through the center hole of the Easy Aimer until the conduit is at the
desired point within the Easy Aimer (typically midway).
3.
Tighten the conduit gland to secure the conduit and transducer assembly in place.
4.
Install the supplied locknut as shown, and complete the conduit installation.
optional M20 cable gland
and coupling
76 mm (3")
nominal
12.7 mm
(0.5")
127 mm (5")
ø (typical)
7ML19985HG61
mounting hole - 3 places, to suit M8 or 3/8" , 120°
apart on 157 mm (6.2") bolt center diameter
angle block binding
screw and clamp
sighting block binding
screw and clamp
ground screw
conduit
gland
20°
Easy Aimer 2 – INSTRUCTION MANUAL
3/4" NPT or BSP conduit x
300 mm (12") long
angle block
sighting block
mounting block
customer gasket
(as required)
customer mounting plate
(as required)
coupling (typical)
Milltronics
transducer (typical)
Page 1