Installation and Aiming
1.
Install the Easy Aimer LR and SITRANS LR 400 by bolting the mounting block directly
to the vessel or bin or via the customer supplied mounting plate.
2.
By manipulating the angle of the Easy Aimer, aim the LR 400 at the desired point
where performance is at optimum levels.
3.
Tighten the clamping screws to secure the device at the desired position.
mounting
plate and
hardware
(customer
supplied)
clamping plate (upper socket)
tighten to 27 N-m (20 ft lb)
of torque
gasket (customer
supplied, recommended
thickness 1.5 to 1.8 mm
(0.06 to 0.07")
mounting
plate with
welded studs
(customer
supplied)
7ML19985HG61
basic installation
clamping plate
(upper socket)
sealed installation
Easy Aimer LR – INSTRUCTION MANUAL