HMP−...−KP−...
Piston j
0−stroke [mm]
Fig. 18
Example with linear module
HMP−20−200−...−KP−...:
L = 280 mm + 200 mm = 480 mm
2. Cut plastic tubing to length L.
3. Connect the compressed air tubing and
the plastic tubing with barbed fitting (S),
supplied.
Use pliers to facilitate fitting
(e. g. type ZMS−...).
If the barbed fitting is fitted several times,
the plastic tubing will widen, conse
quently, do not reuse the barbed fitting.
4. Insert the plastic tubing into hole (E) in the end cover, and push it as far as
possible into the opening in the screw plug connector opposite.
S Refasten the housing cover on the HMP−... .
S Fit the HMP−... in the intended location.
To control the HMP−...−KP pneumatically:
Use the directional control valves
S
intended for this purpose (e. g. for
connection as in Fig. 20 with a CP valve
terminal).
Festo HMP−...−KP−... 0408b English
16
20
203
280
Fig. 17
Fig. 19
Ó Ó
Ó
Ó Ó
Ó
Fig. 20
(S)
(E)